International Journal of Clinical Biochemistry and Research (IJCBR) open access, peer-reviewed quarterly journal publishing since 2014 and is published under auspices of the Innovative Education and Scientific Research Foundation (IESRF), aim to uplift researchers, scholars, academicians, and professionals in all academic and scientific disciplines. IESRF is dedicated to the transfer of technology and research by publishing scientific journals, research content, providing professional’s membership, and conducting conferences, seminars, and award more...

Article type

Original Article


Article page

110-113


Authors Details

Ashwini Pandith, Suresh D R*, Srilalitha P


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 403

PDF Downloaded: 296


Evaluation of analytical performance & quality specification of urine biochemical analytes


Original Article

Author Details : Ashwini Pandith, Suresh D R*, Srilalitha P

Volume : 10, Issue : 2, Year : 2023

Article Page : 110-113

https://doi.org/10.18231/j.ijcbr.2023.017



Suggest article by email

Get Permission

Abstract

Background: Urinary biochemical analytes are very important tools for clinical decision making. Total allowable error (TEa) by integrating internal (IQC) and external (EQC) quality control performances are used to evaluate the performance of urinary biochemical analytes along with quality specifications strategy.
Materials and Methods: Alternate 6 months Coefficient of Variation (CV%) and External Quality Assurance Scheme (EQAS) bias% data for urinary biochemistry analytes were collected for the year 2022. TEa calculated for each analyte was calculated based on average CV% and bias%. Total TEa calculated values are compared with optimal, minimal and desirable TEa of each analyte.
Result: TEa values of urinary biochemistry analytes were performing good and fulfilled minimal, desirable and optimal quality requirements except urine creatinine which did not fulfill the minimal standards.
Conclusion: TEa is an excellent quality management tool and quantitatively evaluates analytical performance. The accurate results generated are useful for clinicians for decision-making.
 

Keywords: Urinary biochemical analytes, Coefficient of variation (CV), External quality assurance scheme (EQAS), Total allowable error (TEa).


How to cite : Pandith A, Suresh D R, Srilalitha P, Evaluation of analytical performance & quality specification of urine biochemical analytes. Int J Clin Biochem Res 2023;10(2):110-113

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.