International Journal of Clinical Biochemistry and Research

Print ISSN: 2394-6369

Online ISSN: 2394-6377

CODEN : IJCBK6

International Journal of Clinical Biochemistry and Research (IJCBR) open access, peer-reviewed quarterly journal publishing since 2014 and is published under auspices of the Innovative Education and Scientific Research Foundation (IESRF), aim to uplift researchers, scholars, academicians, and professionals in all academic and scientific disciplines. IESRF is dedicated to the transfer of technology and research by publishing scientific journals, research content, providing professional’s membership, and conducting conferences, seminars, and award more...

Article type

Original Article


Article page

162-168


Authors Details

Neha, Jaskiran Kaur, Anju Sharma, Ridhum, Amandeep Kaur


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 1341

PDF Downloaded: 477


Current Understanding in the Measurement of Low Density Lipoprotein Cholesterol: A Comparison of Direct Measurement by Homogenous Assays versus Calculations


Original Article

Author Details : Neha, Jaskiran Kaur, Anju Sharma, Ridhum, Amandeep Kaur

Volume : 3, Issue : 2, Year : 2016

Article Page : 162-168


Suggest article by email

Get Permission

Abstract

Background: To compare the results obtained by direct homogenous assay for LDL-C to those obtained by Friedwalds and Anandrajas formulas with the assumption that the results obtained by direct assay are most accurate. This was a comparative study for the estimation of LDL-C using two different types of calculation formulas and direct estimation of LDL-C by homogenous method.
Method: Serum Lipids and lipoproteins were measured in 505 fasting samples.  Serum Total cholesterol was measured using CHOD-PAP method first described by Stadman on Siemens Dimensions Clinical Chemistry RXL Analyzer. Triglycerides were measured by Glycerol Phosphate peroxidase - PAP method. Direct LDL-C was measured by a homogenous assay by siemens diagnostics. A- HDL was measured by a homogenous method which uses PEG- cholesterol esterase using kit from siemens diagnostics. This was a comparative study for the estimation of LDL-C using two different types of calculation formulas and direct estimation of LDL-C by homogenous method.
Results: A good correlation was found between D-LDL as compared to both F-LDL and A-LDL. Pearsons coefficient of correlation between F-LDL & D-LDL was 0.891 (p<0.001) which was comparatively better than that between A-LDL & D-LDL which came out to be 0.850.
Conclusion: In conclusion, regarding patients convenience, financial reasons and accuracy we support the reliability of Anandrajas formula as indirect low density lipoprotein estimation – in Punjabi population.   

Keywords:  Anandraja’s LDL, Friedwald’s LDL, Beta Quantification, Calculated LDL, Direct LDL-C


How to cite : Neha, Kaur J, Sharma A, Ridhum, Kaur A, Current Understanding in the Measurement of Low Density Lipoprotein Cholesterol: A Comparison of Direct Measurement by Homogenous Assays versus Calculations. Int J Clin Biochem Res 2016;3(2):162-168

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.