International Journal of Clinical Biochemistry and Research

Print ISSN: 2394-6369

Online ISSN: 2394-6377

CODEN : IJCBK6

International Journal of Clinical Biochemistry and Research (IJCBR) open access, peer-reviewed quarterly journal publishing since 2014 and is published under auspices of the Innovative Education and Scientific Research Foundation (IESRF), aim to uplift researchers, scholars, academicians, and professionals in all academic and scientific disciplines. IESRF is dedicated to the transfer of technology and research by publishing scientific journals, research content, providing professional’s membership, and conducting conferences, seminars, and award more...

Article type

Original Article


Article page

226- 229


Authors Details

Vijaysinh Parmar, Hiren Sanghani, Asha Khubchandani


Article Metrics


View Article As

 


Downlaod Files

   






Article statistics

Viewed: 1640

PDF Downloaded: 791


Use of deproteinizer to eliminate interference of high bilirubin on measurement of serum creatinine by the kinetic jaffe reaction


Original Article

Author Details : Vijaysinh Parmar, Hiren Sanghani, Asha Khubchandani

Volume : 5, Issue : 2, Year : 2018

Article Page : 226-229

https://doi.org/10.18231/2394-6377.2018.0047



Suggest article by email

Get Permission

Abstract

Introduction: Serum creatinine is a useful diagnostic parameter of kidney function. Its concentration reflects glomerular filtration rate. Because of negative interference of bilirubin over creatinine level, may mislead the clinician. The most common and serious problems in the determination of serum creatinine concentration by the kinetic Jaffe method is the negative interference by bilirubin.
Materials and Methods: This cross sectional study was done on 160 patients which have high bilirubin level, taken from B. J. Medical College, Civil hospital, Ahmedabad from August 2013 to December 2013. These samples were studied for interference of total bilirubin on measurement of Serum creatinine level before and after treating with deproteinizer (trichloroacetic acid 0.55 mmol/ltr). Serum bilirubin and serum creatinine level were measured by modified Jendrassik & Groff’s method and kinetic Jaffe’s reaction respectively by using Erba XL-640 fully auto analyzer.
Results: In this study significant difference was found in Serum Creatinine level with the samples of high bilirubin content before and after treating with deproteinizer (trichloroacetic acid) (p<0>Preprecipitation of albumin along with bilirubin by trichloroacetic acid beforehand is suggested as an approach to correct the bilirubin interference.
Conclusion: From this study it is concluded that bilirubin have negative interference on serum creatinine level. And this is corrected by using deproteinizer trichloroacetic acid.

Keywords: Serum Creatinine, Serum bilirubin, Negative .intereference


How to cite : Parmar V, Sanghani H, Khubchandani A, Use of deproteinizer to eliminate interference of high bilirubin on measurement of serum creatinine by the kinetic jaffe reaction. Int J Clin Biochem Res 2018;5(2):226-229

This is an Open Access (OA) journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.